Simulation of a Martian Solar Thermal Power Plant - Diurnal Operation and Power-Efficiency Correlations

From The Space Library

Jump to: navigation, search

Author - V. Badescu et al

Co-Author(s) - V. Badescu; G. Popescu; M. Feidt

JBIS Volume # - 53

Page # - 131-144

Year - 2000

Keywords -

JBIS Reference Code # - 2000.53.131

Number of Pages - 14

[edit] Abstract

A solar thermal power plant operating on Mars surface is analyzed in this work. During analysis meteorological data measured at Viking Landers (VL) sites were used. Our results show that during autumn at VL1 site, properly designed thermal power plant based on flat - plate solar collectors are comparable in performance with PV- based power systems. During a winter dust-storm day the maximum output power is much smaller than during autumn. High efficiency thermal engines is recommended to be used in combination with solar collectors kept perpendicular on Sun's rays. When a horizontal solar collector is considered, the dependence of the maximum output power on optimum solar efficiency seems to be quadratic at both VL1 and VL2 sites. When a collector perpendicular on Sun's rays is considered, this dependence is more complicate, but keeps the quadratic feature. A certain optimum solar efficiency threshold (around 5%) must be exceeded in order the system provide useful power. No obvious difference exists between power plant performance in the two years of VL2 operation.


To BUY this paper click here




JBIS is © 1934-2013 British Interplanetary Society -